6.8 Metadata Extensions: 6.8.1 X-Ray Beam Source: The type of equipment that produced the X-Ray beam: SSRL X-Ray Synchrotron, 3 GeV, 500 mA current, 54-pole wiggler, beamline 6-2 front hutch 6.8.2 Tube Voltage: Voltage applied to the X-Ray source expressed in 6.8.1 N/A 6.8.3 Tube Current: Current applied to the X-Ray source expressed in 6.8.1 N/A 6.8.4 Source Bandwidth: Bremstrahlung or Delta eV. 1.5 eV Si(111) @ 12200 eV 6.8.5 Source Intensity: Reference Specimen or Photon Count 6.8.6 Scan Matrix Dimensions X by Y In HDF Files, read in SMAK 6.8.7 Beam Dimension 100 micron diameter tungsten pinhole 6.8.8 Beam Scan Spacing 120 microns 6.8.9 Scanning Mode: Continuous, one directional 6.8.10 Scanning Speed: 120 micron/ 8 ms 6.8.10.1 Pixel Acquisition Time: The dwell time of the X-Ray Beam in milliseconds Uscan data log file 6.8.10.2 Time for Scan: Length of time for scan in hours and minutes Data log file around 2000x1300 points 6.8.11 Beam Distance from Specimen: ~ 40 mm. 6.8.12 Beam Angle to Specimen: The angle of the object to the beam in degrees going counterclockwise starting at the beam looking down, or “right hand rule”thumb up. 45 degrees 6.8.13 Lens ENTRY: Polycapillary or Monochromator Si 111 for both 10-2 and 6-2 6.8.14 Primary Beam Filter: Filter material or type between the X-Ray Beam and the object. 6-2 None 10-2 Filter No. 1, then no filter at 023r-030v 3/11 1355 6.8.15 Detectors: Number of XRF detectors. 6-2 2 Front: Vortex ME4-300 running 3 elements Back: Vortex 60EX acting as element 4 Hgf5 data Channel 0 is 3 element, Channel 1 is 1 element 10-2 1 Vortex 90EX Edwards et al, J. Synchrotron Rad, 25, 1565-73 (2018), DOI: 10.1107/S1600577518010202 6.8.15.1 Detector Identification: Name of the XRF detector in the collection system. Edwards et al, J. Synchrotron Rad, 25, 1565-73 (2018), DOI: 10.1107/S1600577518010202 6.8.15.2 Longitude: The angle of the detector horizontally around the object in degrees going counterclockwise starting at the beam looking down, or “right hand rule” thumb up. Front: 90 degrees to the incident beam direction 6.8.15.3 Latitude: The angle of the detector vertically around the object in degrees going down in a clockwise direction starting at the beam looking from the left of the beam, or “right hand rule” thumb toward X-Ray source. 0 (Horizontal) 6.8.15.4 Distance: Distance from the specimen to the detector. 10-2 2.5 cm with collimator and single 25 micron foil filter 6-2 6.5 cm, no filter 6.8.15.5 Detector Make: Make of the detector. See Edwards et al, above 6.8.15.6 Detector Model: Model of the detector. See Edwards et al, above 6.8.15.7 Detector Bias Voltage: See Edwards et al, above 6.8.15.8 Amp Time Constant: milliseconds See Edwards et al, above 6.8.15.9 Make of Counting Electronics: Detector 1: 12.5 micron Beryllium, see Edwards et al JSR 2019 6.8.15.10 Model of Counting Electronics: Detector 1: 12.5 micron Beryllium, see Edwards et al JSR 2019 6.8.15.11 Primary Detector Window: Type of material and thickness in millimeters of the detector window. Detector 1: 12.5 micron Beryllium, see Edwards et al JSR 2019 6.8.15.12 Number of Detector Elements: Number of detector elements behind the window. 6-2 Detector 1: 3 Elements 6-2 Back and 10-2: 1 Element 6.8.15.13 Intermediate Windows: Number of intermediate windows between primary detector and object, and type of material and thickness of windows. 10-2 foil single sheet aluminum foil 25 microns 6.8.15.14 Intermediate Atmosphere: Intermediate atmosphere between detector and object Air 6.8.16 Chamber Atmosphere: The atmosphere in the chamber, either “Air” or a given gas. Air 6.8.17 Chamber Temperature: Approximately 77F 6.8.18 Chamber Humidity: Approximately 32% RH 6.8.19 Post Processing Module: 6.8.19.1 Second Post Processing Module: 6.8.20 Ion Chamber 6.8.20.1 Ion Chamber Length: Length of the ion chamber in centimeters I1 30 cm 6.8.20.2 Type of Gas: Sensing medium in the ion chamber. I0 Helium I1 Air 6.8.21 Gain: I0= 0.19 Gain 1x10-7 6.8.22 Voltage to Frequency Ratio: 105 6.8.23 Channels: Number of channels in the ASCII File: NA 6.8.23.1 Channel Number: The identification number assigned to a given channel NA 6.8.23.2 Detector: The detector output that is assigned to a given channel I0 Strm I1 Strm 6.8.23.3 Element: The natural element collected in a given channel NA 6.8.23.4 Windows: NA